Rules and automations

Rules are managed in an aquarium’s Rules (Règles) tab. They are compiled into the controller’s firmware and apply even without a server.

Type Example Sensor
Threshold Temperature > 27 °C Numeric (temperature probe)
State Low float switch active On/off (level)
Time window Between 22:00 and 07:00 None, RTC clock required

Threshold operators are >, >=, < and <=. A time window can span midnight. Several conditions are combined with AND (all true) or OR (at least one true).

A rule turns one or more pieces of equipment on or off when its conditions are met.

With the return to the previous state option, the equipment goes back to the state it was in when the condition ends. Example: turn off the flow during feeding, then restart it.

A rule marked as a safety lock prevents the equipment from being switched back on while the condition is active, even by hand. Example: cut the heater above 28 °C.

The maximum run time limits how long a device can run continuously. It’s essential for an ATO: if the float switch sticks, the pump stops after the delay and a fault is raised. It must be acknowledged before the pump can restart.

A probe that stops sending measurements triggers an alert instead of being ignored.